Hi Balaji,
Do this:
1. Create a DUMMY selection, let's call it DUMMY_SEL..
2. Insert your CALDAY and any keyfigure in that selection..
3. Create a filter for CALDAY, let's call it ZDAY_RANGE..
General Tab
Processing By: MANUAL INPUT/DEFAULT VALUE
Details Tab
Variable Represents: INTERVAL
Variable Is: MANDATORY
4. In the FILTER tab of query designer, drag the ZBEGDAT and ZENDDAT fields..
5. Create a filter for ZBEGDAT, let's call it ZSTART..
General Tab
Processing By: REPLACEMENT PATH
Replacement Path Tab
Replace Variable With: VARIABLE
Variable: ZDAY_RANGE
Use Interval: FROM VALUE
6. Create a filter for ZENDDAT, let's call it ZEND..
General Tab
Processing By: REPLACEMENT PATH
Replacement Path Tab
Replace Variable With: VARIABLE
Variable: ZDAY_RANGE
Use Interval: TO VALUE
You can now run your report..![]()
Just post here for any queries..
Regards,